DYN(S)-A Series

Non-isolated constant current linear dimmable driver

 

Features
·Input and output non-isolated
·Support DALI-2 DT6+D4i dimming mode
·Quickly install the sensor and the wireless control module through the D4i interface
·Input AC and output DC power metering
·Support EnergyData function and energy-reporting reading (DALI Part 252)
·Support Luminaire data reading (DALI Part251), support diagnostics-maintenance reading (DALI Part253)
·Support advanced functions such as EL, CLO
·The output current programming can be realized through the DALI interface or NFC interface
·Support 20 units/batch, batch programming
·Suitable for emergency lighting acc. to EN 50172
·Soft dimming and flicker-free at any brightness, meets the new requirements of ErP certification
·Using HPC patented technology, at any dimming level, the brightness of the luminaries is the same
·Dimming range 1~100%
·Standby power input < 0.5W, meets the requirements of ErP certification
·High PF, high efficiency, low THD
·Suitable for built-in use of Class I lamps
·Compliance with CE,ENEC,UKCA,RCM,CCC,DALI-2,EL,D4i and other certifications
·Compliance with Zhaga Book 13/24/25 standards
·IP20 protection grade, indoor use
·Nominal life-time up to 100,000 h
·5.5-year guarantee

Parameters

Model

Input voltage

Output power

Output voltage

Output current

PF

Efficiency

THD

Ta

Tc

Dimension(mm)

BK-DYN040S-A0400ADP

BK-DYN040S-A0400ADN

200-240VAC

40W

50-250VDC

0.05-0.4A

0.97

91.5%

9%

60°C

90℃

L280*W30*H21

BK-DYN080S-A1050ADP

BK-DYN080S-A1050ADN

200-240VAC

80.85W

50-250VDC

0.1-1.05A

0.98

93.5%

9%

60°C

90℃

L360*W30*H21

Suffix DP:DALI-2 DT6+D4i+EnengyData+EL+CLO+DALI programmable
Suffix DN:DALI-2 DT6+D4i+EnengyData+EL+CLO +DALI programmable+NFC programmable

Specifications

Item

Parameter

Rated input voltage

200-240VAC 200-240VDC

Limited voltage

180-264VAC 180-264VDC

Input votage shock

380V

Output type

non-SELV

Output current accuracy

5%

Dimming range

1-100%

Power on time

<0.7s(AC start),<0.7s(DC start),<0.3s(AC/DC switchover),<0.5s(Turn off )

Standby power

<0.5W

Surge

L-N:2KV,L-FG/N-FG:2KV

Flicker-free

Pst LM <1,SVM <0.4

Operation temperature

-20°C-60°C

Protection class

IP20

Life time

Normal 100,000 hours

Warranty

5.5 years

Dimension(unit:mm)

Wiring diagram